Quick Take
Running software in a renewable-powered data centre does not eliminate the energy consumed by the software itself. Sustainability by Design asks a more demanding question: can we deliver the same useful business outcome with fewer computations, less data movement and less idle capacity? The answer starts before deployment—with the functionality we choose to build, the algorithms we implement, how frequently we process data and the cloud resources we consume. GreenOps and efficient infrastructure matter, but software design determines much of the workload they must operate.
Sustainability reporting frequently concentrates on the electricity used by infrastructure. That is necessary, but it can leave one expensive assumption unchallenged: the application consuming that electricity must be doing something useful. A technically efficient hosting environment can still spend enormous resources on redundant features, repeated calculations and data pipelines that nobody uses.
The 2023 LinkedIn article ‘Sustainability by Design’ raised the relationship between digital solutions and their environmental cost. This draft is a newly authored companion piece based on that theme and the later public discussion of Sustainability by Design. The full original LinkedIn text was not accessible for a sentence-by-sentence comparison, so this must not be presented as a complete migration of the 2023 article.
The surviving opening of the August 2023 article put AI-related electricity demand at the centre of this argument. It contrasted the energy used in training large AI systems and operating data centres with growing demand for electricity from electric cars, heat pumps and other essential services. That is part of the historical argument and belongs in this archive. Its eye-catching 2023 comparisons, including an estimate equating a single AI training run to the annual consumption of 120 households and a prediction that data centres could use 10% of global electricity by 2030, are not independently substantiated in the available original material. I would not repeat them as established facts.
For scale, the International Energy Agency’s 2026 analysis estimates that global data centres used around 485 TWh in 2025 and projects roughly 950 TWh in 2030, about 3% of worldwide electricity demand. The precise figures evolve with technology and demand, but the design problem has become more relevant: AI and cloud workloads compete for power in grids that have other urgent obligations.
Start by deciding what should not run
The cleanest application workload is one that was never necessary. Software lifecycle management should ask whether a feature, scheduled process, duplicate integration or data collection job still serves a current purpose. Functionality kept for historical reasons can quietly consume infrastructure long after its business value has disappeared.
This is not an argument against useful digital services. It is an argument for making business demand explicit: who uses this function, what decision does it improve, how much work must the system do, and when can it safely be switched off? The same questions that help prevent technical debt also prevent avoidable energy demand. This is closely related to the argument in Can Burning More AI Tokens Actually Make Software Greener?: avoiding unnecessary functionality can matter more than optimising it.
How to measure software energy efficiency before optimising
Application-level sustainability is difficult to manage when teams see only a monthly cloud bill. Cloud pricing can provide a signal about consumption, but cost is not the same as energy or emissions. A credible baseline should distinguish compute time, memory, storage, network traffic and the volume of business transactions. The indicator that matters is often energy per useful outcome rather than total energy alone.
If a service grows, its absolute consumption may increase even while each transaction becomes more efficient. Conversely, reducing costs by changing billing arrangements may have no meaningful effect on electricity use. Measurement needs a defined boundary and workload so that a before-and-after comparison says something useful.
Avoid retraining and processing data without a reason
AI systems illustrate the cost of unnecessary repetition. Models may need monitoring for drift, but a fixed calendar for retraining is not a substitute for examining whether the data, requirements or performance have actually changed. Retraining also needs to account for the time, resources and verification required. A sensible policy chooses retraining when evidence supports it, while keeping necessary safety and performance controls.
The same principle applies to ordinary integration. Fetching the same data repeatedly from an external registry or recalculating an unchanged result uses infrastructure without adding information. Appropriate caching, event-driven updates and measured data-retention policies can eliminate avoidable work. These mechanisms also introduce consistency and privacy concerns, so they need proper expiry and invalidation rules.
Choose efficient code and architecture, not slogans
The execution cost of a workload depends on algorithms, data structures, queries, runtime, hardware and how the system is configured. A language label by itself is a poor energy-efficiency measurement. An efficient database query in one environment can outperform a poorly designed implementation in another regardless of which programming language created it.
Engineering teams should profile actual bottlenecks and optimise where it changes the outcome. A query that is issued hundreds of times for one request, redundant service calls and repeated transfer of large datasets are often better starting points than replacing a whole technology stack because of a fashionable comparison of languages.
Treat cloud capacity as a design decision
Cloud services can hide inefficiency by scaling automatically. When response times remain acceptable, a team may not notice that a small increase in application demand triggers a much larger increase in resource use. Good capacity management requires collaboration between developers, architects, platform specialists and operations teams.
Autoscaling, scheduled shutdown of unused test environments, right-sized instances and event-driven components can help under the right workload. Serverless is not automatically greener: consumption depends on execution patterns, infrastructure, and system boundaries. Test environments should represent meaningful workload characteristics, not only contain a fraction of production data that makes every design appear efficient.
A practical baseline for green software decisions
Start with one representative transaction, data-processing job or business outcome. Measure the current workload’s electricity use where instrumentation allows it, alongside processing time, data transferred and required capacity. Keep the hardware, traffic and quality-of-service assumptions consistent when comparing changes. Then check whether a more efficient implementation actually reduces provisioned infrastructure or merely creates room for extra demand. Report estimated savings separately from measured electricity and carbon outcomes; do not mistake a lower cloud bill or faster response time for proof of lower emissions.
An acceptance test for energy-efficient software
Consider a scheduled data pipeline that a team wants to make more efficient. A faster run or a lower cloud bill is not sufficient evidence of lower energy consumption. Compare the old and new implementations on the same representative data and infrastructure, while preserving the required accuracy, security and service levels. Before accepting the change, check:
- Does it deliver the same useful outcome, with the same data quality and acceptable response or processing times?
- What changed in measured electricity use per completed outcome? If direct measurement is unavailable, which compute, memory, storage and network indicators are being used as proxies?
- Has work simply moved elsewhere, for example to another service, additional network transfers or longer data retention?
- Can the efficiency gain actually reduce active or provisioned capacity, or does it merely create spare capacity without reducing demand?
Record the workload, measurement boundary, test duration and uncertainty. Keep energy measurements, resource proxies, estimated emissions and cost savings separate in the result. An optimisation should be judged by its measured system-wide effect, not by an attractive single metric.
Make sustainability part of engineering governance
Sustainability needs to become a normal design concern alongside performance, security, reliability and cost. That means architecture decisions record energy-related trade-offs, automated tests can detect significant regressions, and delivery teams keep monitoring after deployment. Procurement can ask suppliers for meaningful measurements and evidence, rather than relying on generic green hosting claims.
GreenOps focuses on the operation and provisioning of technology. Sustainability by Design begins earlier, with what the software asks the infrastructure to do. The two belong together. Without a clear business purpose and credible measurements, either becomes another dashboard of good intentions.
Editorial source note: Newly authored draft referring to Robbrecht van Amerongen’s LinkedIn article of 4 August 2023, Sustainability by Design: Driving Green Solutions in Digital Technology, and the later Conclusion interview on Sustainability by Design. This is an original companion essay, not a full reproduction or verified translation of the 2023 LinkedIn publication. The complete source text was unavailable for a paragraph-by-paragraph comparison; the August 2023 date marks the original argument, while this expanded English edition was prepared in November 2026.
Related reading: ESG Reports: Why Sustainability Needs Action; AI Data Centres and the Power Grid.
